Fully Installed Cooling and Heating System from £899

We are offering fully installed Cooling and Heating systems from £899. Get in touch with us today to get yours. We will also give you a free quote and free site survey first.

Is it just servicing you’re after? We’re also offering servicing from £99 per unit including free treatment with an Alkaline Evaporator Cleaner and Disinfectant with QX-60 that kills 99.9% of bacteria and fungi in less than 60 seconds. This improves the energy efficiency of your unit as well as the indoor air quality. The cleaner is approved by Aspen Pumps and other leading condensate pump manufacturers.

Fungi, bacteria and other microbes that develop on coils in air conditioning units can become the source of allergic reactions, horrible odours and the spread of diseases. Our cleaner thoroughly disinfects the coils as well as the trays in your air conditioning or refrigeration systems (this includes evaporators in food preparation areas). The CodenCide cleaner complies with British & European Standards for Bactericides & Fungicides BS/EN 1276 & BS/EN 1275.

You can find out more about our servicing and maintenance of air conditioning units or get in touch with is directly to order yours today.

, , ,

2 Responses to Fully Installed Cooling and Heating System from £899

  1. Jonathan Leonhart May 2, 2012 at 4:27 pm #

    Hi,
    My flat has a Daikin split system air conditioner. There are three inside, above-the-ceiling mounted (although accessible) a/c ‘blowers, each with a separate wall mounted control, and all connected to a single outdoor compressor (R410A split series).
    Two of the three units are cooling normally. With the third, the wall control unit registered a fault yesterday, so won’t do anything until that fault is resolved. If it helps, the read out shows an eye and wrench, indicating servicing is needed, and flashed ‘No 0″ and ‘A3″.
    Your availability for repair and a rough price estimate would be appreciated! I’d also be interested in coil cleaning mentioned on your website. How much mess does this create, and is there any issue breathing the cleaning fluid?
    Jonathan

    • jonathan May 3, 2012 at 6:19 pm #

      Hi There, an A3 error code is Malfunctioning Drain Water Level Sysytem.

      This could mean a number of causes.

      The lift pump has malfunctioned
      Improper drain piping work
      A blogged drain
      Malfuntioning float switch
      Faulty indoor circuit board
      The connection on X15 short circuit.

      It could just be a blockage.

      It would cost £95 + vat for 1 hour engineers labour. If its a blockage that will be the only charge. If it is some thing else, we would give you a fixed price for the repair.